11-13
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Keypad
Keypad
Description Possible Reason for Trip
FERR FIRMWARE ERROR
♦ The firmware in the drive has stopped executing
RSLV RESOLVER ERROR
See function block
description
♦ Resolver incorrectly wired
♦ Resolver not compatible with resolver feedback
option board
♦ Resolver length cable too long
♦ Incorrect Resolver Function Block settings
MI2T I2T MOTOR TRIP
See function block
description
♦ Motor is undersized
STO SAFE TORQUE OFF -
♦ The safe torque off feature has been activated. See
Chapter 6, STO Trip Annunciation.
REFC REF ENCODER CAL
The drive has failed to set
absolute position
♦ Check the encoder supports absolute position, and
that the encoder is wired correctly.
REFF REF ENCODER FAIL -
♦ Function not implemented
DCFG DRIVE CONFIG ERR Drive configuration error
♦ The configuration defined in DRIVE CONFIG
doesn't match the actual drive configuration.