Trips & Fault Finding
11-13
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
6511
Keypad
Display
6901
Keypad
Display
Description Possible Reason for Trip
FERR FIRMWARE ERROR
The firmware in the drive has stopped executing
RSLV RESOLVER ERROR
See function block
description
Resolver disconnected
Resolver incorrectly wired
Resolver not compatible with resolver feedback
option board
Resolver length cable too long
Incorrect Resolver Function Block settings
MI2T I2T MOTOR TRIP
See function block
description
Motor is undersized
STO SAFE TORQUE OFF -
The safe torque off feature has been activated. See
Chapter 6, STO Trip Annunciation.
REFC REF ENCODER CAL
The drive has failed to set
absolute position
Check the encoder supports absolute position, and
that the encoder is wired correctly.
REFF REF ENCODER FAIL -
Function not implemented
DCFG DRIVE CONFIG ERR Drive configuration error
The configuration defined in DRIVE CONFIG
doesn't match the actual drive configuration.