6 Installation
Instruction book, IQAN- XA2
6 Installation
Connector C1
Connector pin assignments
Connector kit Parker no. 5031063
Housing Amp no. 1-963226-1
Casing Amp no. 0-965643-1
Plane sealing, 42 p installed in module
Pin types* Amp no. 963711-2 (MT) Amp no. 929938-1 (JPT)
Cables 0,75-1,0 mm² (MT) 1,5-2,5 mm² (JPT)
Seals Amp no. 963530-1 (MT) Amp no. 828905-1 (JPT)
Plugs (empty pos.) Amp no. 963531-1 (MT) Amp no. 828922 (JPT)
IQAN crimping tool
references
Blue handle, pos. A
use blue extraction tool
Red handle, pos. B
use yellow extraction tool
IQAN tool kit Parker no. 5031061
Logical
Symbol
Pin
No.
(I)nput or
(O)utput
Function description
and/or Signal name(s)
+BAT 28 - Power supply, positive.
-BAT 15 - Power supply, negative ground
+VREF 42 - Voltage reference for external sensors. Sourcing +5V.
-VREF 29 - Voltage reference for external sensors. Return (0V).
ADDR-H 1 - High side to address tag. Sourcing +5V.
ADDR-L 14 - Low side to address tag. Return (0V).
CAN-H 26
27
-
-
CAN high voltage bus line, will be HIGH in dominant state.
CAN-L 40
41
-
-
CAN low voltage bus line, will be LOW in dominant state.
*= The connector contains two types of terminals;
MT (Micro Timer) and JPT (Junior Power Timer).
42
28
14
29
15
1
+BAT ADDR-H
ADDR-L
CAN-H
CAN-L
PORT 1
PORT 2
-BAT
+VREF
-VREF
PORT 0
XA2