5
IQAN-XA2
3 Product description
Instruction book, IQAN- XA2
3 Product description
IQAN-XA2
The IQAN-XA2 is a flexible expansion module designed for controlling hydraulic
systems in vehicles and machinery, using 12/24 Vdc power supply.
The IQAN-XA2 module.
I/O overview
Inputs
The IQAN-XA2 module has eight (8) voltage inputs VIN-A thru VIN-H for connection
of 0-5 Vdc signals. The inputs VIN-E thru VIN-H are multi-purpose and for flexibility
may be configured in other ways. The two input pins VIN-E and VIN-G can be
configured as frequency inputs for measuring frequency. The group of four pins VIN-E
thru VIN-H can be configured as quadrature or directional inputs for measuring
directional frequency. Voltage inputs, frequency inputs, quadrature inputs and
directional inputs share positions, see below.
(8) Voltage inputs VIN-A, VIN-B, VIN-C, VIN-D.....VIN-H
or
(6) Voltage inputs VIN-A thru VIN-D,VIN-F and VIN-H.
(2) Frequency inputs FIN-A and FIN-B use positions VIN-E and VIN-G.
or
(4) Voltage inputs VIN-A thru VIN-D. (2) Quadrature or Directional inputs
DFIN-A+/DFIN-A- and DFIN-B+/DFIN-B- use positions VIN-E thru VIN-H.
or
(8) Digital inputs DIN-A, DIN-B.....DIN-H use positions VIN-A thru VIN-H.
+BAT ADDR-H
ADDR-L
CAN-H
CAN-L
PORT 1
PORT 2
-BAT
+VREF
-VREF
PORT 0