Motor will require a current I of T/Kt = 5.35 / 1.2548 = 4.267 Arms.
Total Voltage Requirement on the motor leads between phase to neutral is:
Uphase to neutral = 123.4 V
Uphase to phase = 123.4 x 3
Uphase to phase = 213.7 V
Parker has a range of 3 windings that are available for each stack length within a
particular frame size to meet the majority of your application requirements. Parker does
have additional windings that are available upon request from Parker’s Application
Engineering Department.
Use the performance specifications on the following pages to help determine the best
solution for your specific application requirements.