3.5. Natural cooled motor
In compliance with the IEC 60034-1 standards: the ambient air temperature shall not
be less than -15°C and more than 40°C.
K Series Kit are housed in a motor frame detailled in § 3.4.4.1 Stator
Warning: To reach the motor performances calculated, the complete
motor must thermally well connected to a aluminium flange with the
following dimensions:
- K032 : 25.4 cm×25.4 cm×0.635 cm (S=1355 cm²)
- K044 : 25.4 cm×25.4 cm×0.635 cm (S=1355 cm²)
- K064 : 25.4 cm×25.4 cm×0.635 cm (S=1355 cm²)
- K089 : 30.48 cm×30.48 cm×1.27 cm (S=2013 cm²)
- K178 : 40.64 cm×40.64 cm×2.54cm (S=3716 cm²)
Caution: the ambient air temperature shall not exceed 40°C in the
vicinity of the motor flange
Warning: A significant part of the heat produced by the motor is
evacuated through the flange.
if the air is not able to circulate freely around the motor,
if the motor is mounted on a surface that dissipates not well the
heating (surface with little dimensions for instance),
if the motor is thermally isolated,
if the motor is mounted on a warm surface (mounted on a gearbox
for instance),
then the motor has to be used at a torque less than the rated torque.