EasyManuals Logo

Parker K Series User Manual

Parker K Series
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9 - PVD 3674_GB_K Series_CE-November 2016.Docx
2.5. General Technical Data
Motor type
Permanent-magnet synchronous motor
Magnet material
Nd-Fe-B (Neodymium Iron Boron)
Number of poles
Size:
K044
K064
K089
K178
Nbr of
poles:
6
8
12
18
Degree of protection
IP00
Cooling
Natural cooling
Altitude
Up to 1000m (IEC 60034-1)
(for higher altitude see §3.1.1 for derating)
Rated Supply voltage of drive
115 VAC for size 32, 44, 64 and 89
240 VAC for size 178
Rated Supply voltage of motor
100 VACrms phase to phase
for size 32, 44, 64 and 89
214 VACrms phase to phase for size 178
Connections
Power cables
Insulation of the stator winding
Class F according to EN 60034-1
Operating temperature
-15°C to +40°C for natural cooling version (IEC
60034-1)
Storage temperature
-20… +60°C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker K Series and is the answer not in the manual?

Parker K Series Specifications

General IconGeneral
BrandParker
ModelK Series
CategoryServo Drives
LanguageEnglish

Related product manuals