Parameter Address Length Meaning
Pr0 038h 2 motor speed in rpm
Pr1 034h 2 analog reference
Pr2 03Ah 2 full scale 1
Pr3 03Ch 2 full scale 2
Pr4 036h 2 frequency full scale
Pr5 03Eh 2 internal reference
Pr6 040h 2 reserved reference
Pr7 042h 2 chosen reference
Pr8 0AEh 2 positive acceleration in seconds
Pr9 0B0h 2 positive deceleration in seconds
Pr10 0B2h 2 negative acceleration in seconds
Pr11 0B4h 2 negative deceleration in seconds
Pr12 0B6h 2 limit switch deceleration
Pr13 0B8h 2 overspeed threshold
Pr14 044h 2 upper speed limit
Pr15 046h 2 lower speed limit
Pr16 048h 2 integral gain
Pr17 0BAh 2 damping factor
Pr18 0BCh 2 filter time constant
Pr19 0BEh 2 user current limit
Pr20 04Ah 2 bus voltage
Pr21 04Ch 2 reserved torque limit
Pr22 04Eh 2 auxiliary reference
Pr23 051h 1 current alarm code
Pr24 052h 1 last alarm code
Pr25 053h 1 software release code
Pr26 05Eh 1 baud rate
Pr27 05Fh 1 serial address
Pr28 0C0h 2 shaft position (0..4095)
Pr29 061h 1 number of poles
Pr30 0C2h 2 offset
Pr31 054h 1 operating mode
Pr32 0C4h 2 motor rated speed
Pr33 0C6h 2 rated current
Pr35 0C8h 2 filter torque demand
Pr36 058h 2 i
2
t accumulation
Pr37 05Ah 2 braking thermal image
Pr38 0CAh 2 auxiliary analog output
Pb40 05Ch 2 flags used by main block
Pb41 056h 2 flags used by main block
Pb42 060h 1 flags used by main block
Pr43 0E8H 2 stack pointer
Pr44 0E4h 2+2 table element
Pr45 0EAh 2 analog input
Pr46 0ECh 2 encoder in LSB
Pr47 0EEh 2 encoder in MSB
Pr48 0F0h 2 LSB dimension capture
Pr49 0F2h 2 MSB dimension capture
Pr50 064h 2
Pr51 066h 2