8 Hot water
2021/03 99E13331xx-mub-en - V07 23
8 Hot water
D.H.W. SET TEMPERATURE
60 °C
60 °C
MIN : 35 MAX : 75
In this menu item, you can make the temperature
settings for the hot water preparation.
Setting options for the following parameters are available:
D.H.W. set temperature: the set hot water temperature which is supposed to be reached
at the outlet of the domestic hot water module
D.H.W. set temperature minimum*: the lower limit for the setting of the hot water
temperature
D.H.W. set temperature maximum*: the upper limit for the setting of the hot water
nominal temperature
Parameters
Meaning
Adjustment
range
Factory setting
D.H. W. set
temperature
Hot water nominal
temperature
35...75 °C 60 °C
D.H.W. set temperature
minimum*
Minimum hot water nominal
temperature
20...45 °C 35 °C
D.H.W. set temperature
maximum*
Maximum hot water
nominal temperature
60...90 °C 75 °C
*Settings only visible with installer code (see chapter "User code").