16 Description of function
2021/03 99E13331xx-mub-en - V07 39
Parameters
Meaning
Adjustment range
Factory setting
Disinfection Activates the function On, Off Off
Manual disinfection Manual start of the
disinfection
On, Off Off
Disinfection temperature Sets the disinfection
temperature
60 ... 80 °C 60 °C
Disinfection duration Sets the duration of the
disinfection
10 ... 240 min 60 min
Disinfection day Week day of the
disinfection
Monday ... Friday -
Disinfection start hour Start time of the
disinfection
0 ... 11:00 p.m. 01:00 a.m.
Disinfection OK after Duration for which the
temperature condition
must be met
9 min ...
Duration of
disinfection 1 min
15 min
Stop before time Activates the automatic
abortion
On, Off Off
Disinfection history History of previous
disinfections
- -
16.6 Alarm relay
The function
Alarm relay
allows to switch a relay in case of an error. For example, a signal
transmitter can be connected which reports errors. If the function is activated, the controller
switches the relay in case of an error.
If the function
Inverted
is activated, the relay is switched if no error is present. If an error occurs,
the controller switches off the relay.
Parameters
Meaning
Adjustment
range
Factory setting
Alarm relay Activates the function On, Off Off
Relay selection Selects the relay Relay 1, Relay 2 -
Inverted Relay function inverted On, Off Off
Pt1000 error Short-circuit / interruption at a
temperature sensor
On, Off Off
VFS/US error Short-circuit / interruption /
exceeding or falling under the
On, Off Off