13 Auto / manual mode
2021/03 99E13331xx-mub-en - V07 29
Properties Properties of the
USB flash drive
- -
13 Auto / manual mode
In this menu item, you can set the operation mode of all used PWM outputs and relays in the
controller as well as a sensor simulation.
With the sensor simulation, a certain temperature can be set for a sensor in order to simulate
this temperature.
The manual mode has the highest priority. These setting
values overwrite the automatic actuating values of the
controller.
If the controller runs in manual mode, a hand symbol is
shown on the display of the system overview.
Parameters
Meaning
Adjustment range
Factory setting
Automatic mode Sets all outputs to
automatic / manual
mode
On (automatic), Off
(manual mode)
On
Sensors simulation Goes to the submenu to
the simulation of the
inputs
- -
Sensor 1 Sensor 1 (T-VL) Automatic, simulation
(-30 ... 150 °C)
Automatic
Sensor 2 Sensor 2 Automatic, simulation
(-30 ... 150 °C)
Automatic
Sensor 3 Sensor 3 Automatic, simulation
(-30 ... 150 °C)
Automatic
Sensor 4 Sensor 4 (T-CW) Automatic, simulation
(-30 ... 150 °C)
Automatic
VFS/US V VFS/US flow rate Automatic, simulation
(0.0 ... 40.0 l/min)
Automatic
VFS/US T VFS/US temperature Automatic, simulation
(-30 ... 150 °C)
Automatic