SGM700 Digitizer
78
5. ACSII -protocol commands - continue-
Command Respons strings Operation
LN<CR> N+00000+00000SSCC<CR>/ERR<CR> Get net+fast net , status & checksum
LX<CR> X+00000+00000SSCC<CR>/ERR<CR>
Get long extended net (net x 10) +
extended gross (gross x 10), status &
checksum
SD<CR> OK<CR>/ERR<CR> Set auto-transmit display value
SN<CR> OK<CR>/ERR<CR> Set auto-transmit net
SG<CR> OK<CR>/ERR<CR> Set auto-transmit gross
SW<CR> OK<CR>/ERR<CR> Set auto-transmit long weight
SP<CR> OK<CR>/ERR<CR> Set auto-transmit peak
SV<CR> OK<CR>/ERR<CR> Set auto-transmit valley
SF<CR> OK<CR>/ERR<CR> Set auto-transmit fast net
SX<CR> OK<CR>/ERR<CR>
Set auto-transmit extended net
(net x 10)
IV<CR> V:0102<CR> Information on Version
ID<CR> D:0502<CR> Information on Device
IS<CR> S:001000<CR> Information on System