9.2 ACSII -Protocol Commands-
Command Respons strings Operation
OP <number><CR> OK<CR>/ERR<CR> Open channel connection
CL<CR> Close channel connection
SZ<CR> OK<CR>/ERR<CR> Set Zero value
RZ<CR>
OK<CR>/ERR<CR>
Reset Zero value
ST<CR>
OK<CR>/ERR<CR>
Set Tare
RT<CR>
OK<CR>/ERR<CR>
Reset Tare
PT<value><CR>
OK<CR>/ERR<CR>
Get/Set Preset Tare
PS<CR>
OK<CR>/ERR<CR>
Activate preset Tare
RP<CR>
OK<CR>/ERR<CR>
Reset Peak
RV<CR>
OK<CR>/ERR<CR>
Reset Valley
GD<CR>
OK<CR>/ERR<CR>
Get Display value
GN<CR>
N+00000<CR>
Get net
GG<CR>
G+00000<CR>
Get gross
GP<CR>
P+00000<CR>
Get peak
GV<CR>
V+00000<CR>
Get valley
GF<CR>
F+00000<CR>
Get fast net (no display damping)
GS<CR>
S+00000<CR>
Get A/D sample
GW<CR>
W+00000+00000SSCC<CR> Get long net+gross, status &
checksum
GX<CR>
X+00000<CR>
Get extended net (net x 10)
LW<CR>
W+00000+00000SSCC<CR>/ERR<CR> Get long net+gross, status &
checksum
LF<CR>
F+00000+00000SSCC<CR>/ERR<CR>
Get long fast net+gross, status &

Related product manuals