What to do if my Pentair Water Filtration System brine tank overflows?
J
Jessica OwensAug 17, 2025
If your brine tank overflows, it could be due to several reasons. An uncontrolled brine refill flow rate might be the issue, in which case you should remove the brine controller to clean the ball and seat. Another possible cause is an air leak in the brine line to the air check; inspect all connections in the brine line for leaks. Lastly, the drain control could be clogged with resin or other debris, so cleaning the drain control might solve the problem.
G
Gregory RobinsonAug 20, 2025
Why is my Pentair Water Filtration System leaking hard water after regeneration?
B
Bradley FordAug 20, 2025
Hard water leakage after regeneration can occur due to several reasons. It could be caused by improper regeneration, so try controlling the brine dosage setting and repeating the regeneration. A leaking external bypass valve can also be the culprit, requiring replacement of the bypass valve. Another potential cause is a damaged O-ring around the riser pipe, which would need replacing. Lastly, an incorrect capacity setting could lead to this issue, so verify the appropriate brine amount and system capacity.
J
Joseph SmithAug 23, 2025
Why won't my Pentair Water Filtration System controller draw brine?
J
Jennifer HammondAug 23, 2025
If your controller isn't drawing brine, consider the following potential causes: low water pressure, which requires adjusting the settings according to the instructions; a restricted drain line, which needs the restriction removed; a plugged injector, requiring cleaning of the injector and screen; a defective injector, which means you should replace the injector and cap; valve disc 2 and/or 3 not closed, so remove any foreign matter from the disc and check if the disc can close by pushing on the stem, replacing the disc if needed; or the air check valve prematurely closed, so put the controller momentarily into brine refill (C8 - cycle) and replace or repair the air check if needed.
C
Carrie HatfieldAug 26, 2025
Why is my Pentair Water Filtration System valve not drawing brine?
R
Randy HuynhAug 26, 2025
If the valve isn't drawing brine, possible causes include low water pressure, so set the pump to maintain 1.4 bar at the softener. Another reason could be a restricted drain line, so change the drain to remove the restriction. Additionally, the injector might be plugged, necessitating cleaning of the injector and screen, or the injector could be defective, requiring replacement. Finally, the air check valve may be closing prematurely, so put the controller momentarily into brine cycle (C2) and replace or repair the air check if needed.
S
saraperkinsAug 28, 2025
What to do if Pentair Water Filtration System is dripping water after regeneration?
R
robertsdavidAug 29, 2025
If you notice flowing or dripping water at the drain or brine line after regeneration, it might be due to a weak valve stem return spring, in which case you should replace the spring. Alternatively, the valve disc might not be closing properly due to debris, requiring you to remove the debris.
J
Jason GilbertAug 31, 2025
How to fix Pentair Water Filtration System regenerating at wrong time?
M
Mr. Marcus OconnorAug 31, 2025
If your controller regenerates at the wrong time, it's likely that the controller is set incorrectly. Correct the time setting according to the instructions.
R
robertsontiffanySep 3, 2025
Why doesn't my Pentair Water Filtration System controller regenerate automatically?
J
Jesus DavisSep 3, 2025
If your controller isn't regenerating automatically, make sure the AC transformer or motor are connected. If they are already connected, the motor might be defective, requiring replacement.
S
Sheila SuttonSep 5, 2025
Why is my Pentair Water Filtration System using incorrect salt amount?
J
Jennifer MurphySep 5, 2025
If the system uses more or less salt than the brine setting, it may be due to foreign matter in the valve causing incorrect flow rates. Remove the brine controller and flush out any foreign matter. Then, advance the controller to the brine cycle (C2) to clean the valve; afterward, the controller goes to the "2nd fast rinse" cycle (C7) to remove any brine from the tank.
J
josephparksSep 8, 2025
What to do if Pentair Water Filtration System shows ERR3?
G
gonzalezstephenSep 8, 2025
If your system displays 'ERR3', it indicates that the controller lost the position of the camshaft. First, wait for 2 minutes to allow the controller to return to the Home position. During this time, an hourglass icon will flash, indicating that the motor is running. If the camshaft doesn't rotate, check the motor connections, ensure the motor wire harness is connected to both the motor and the controller, verify the optical sensor connection and position, and confirm that the motor and camshaft gears are engaged. If the camshaft rotates for more than 5 minutes to find the Home position, check the optical sensor connection and position, the camshaft connection, and the cleanliness of the camshaft slots.