EasyManua.ls Logo

Pentair Autotrol 255 Logix 740-760 - Description; Technical specifications

Pentair Autotrol 255 Logix 740-760
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual 255-LOGIX 740-760 - Description
Ref. MKT-IM-001 / C - 08.10.2019 13 / 76
3. Description
3.1. Technical specifications
Design specifications/ratings
Valve body ......................................................................... Glass-filled Noryl
®
- NSF listed material
Rubber components ......................................................... Compounded for cold water - NSF listed
material
Valve material certification .............................................. WQA Gold Seal Certified to ORD 0902, NSF/
ANSI 44, CE, ACS
Weight (valve with controller)........................................... 1.8 kg
Recommended operating pressure ................................. 1.4 - 8.6 bar
Hydrostatic test pressure................................................. 20.69 bar
Water temperature........................................................... 1 - 38°C
Ambient temperature ....................................................... 2 - 50°C
Flow rates (valve only)
Service at 1.03 bar (15 psi) drop....................................... 3.52 m
3
/h
Backwash at 1.72 bar (25 psi) drop .................................. 1.36 m
3
/h
Service .............................................................................. Kv = 3.4 m
3
/h (Cv = 3.99 gpm)
Backwash.......................................................................... Kv = 1.0 m
3
/h (Cv = 1.20 gpm)
Valve connections
Tank Adapter Thread ........................................................ 63.5 mm (2½") - 8, male
Inlet/Outlet Maniflold ....................................................... 25.4 mm (1") NPT or BSPT, female (brass or
thermoplastic) 19 mm (¾") NPT or BSPT,
male (thermoplastic) 2.7 (½") NPT or BSPT,
male (thermoplastic)
Drain line 12.7 mm (½") (manifold
dependent)
Brine line .......................................................................... 9.5 mm (⅜") NPT as standard, 6.35 mm (¼")
NPT optional; air check built onto valve
Riser tube [Ø].................................................................... 27 mm (1.050") standard, or 20.6 mm
(0.8125") optional with extra insert
Riser tube [length]............................................................ 29 mm ± 3 mm (1⅛ ± ⅛") above top of tank
Electrical
Controller Operating Voltage ........................................... 12 VAC (requires use of Pentair Water
supplied transformer)
Input Supply Frequency.................................................... 50 or 60 Hz (controller configuration
dependent)
Motor Input Voltage .......................................................... 12 VAC
Controller Power Consumption ....................................... 3 W average
Protection rating............................................................... IP23

Table of Contents

Related product manuals