Installer Manual 255-LOGIX 740-760 - Installation
Ref. MKT-IM-001 / C - 08.10.2019 25 / 76
5.3. Integration constraints
Location of a water treatment system is important. The following conditions are required:
level platform or floor;
room to access equipment for maintenance and adding brine (salt) to tank;
constant electrical supply to operate the controller;
total minimum pipe run to water heater of 3 m to prevent backup of hot water into system;
always install check valve to protect the softener from hot water return;
local drain for discharge as close as possible;
water line connections with shut off or bypass valves;
must meet any local and state codes for site of installation;
valve is designed for minor plumbing misalignments. Do not support weight of system on the
plumbing;
be sure all soldered pipes are fully cooled before attaching plastic valve to the plumbing.