Installer Manual 255-LOGIX 740-760 - Programming
Ref. MKT-IM-001 / C - 08.10.2019 41 / 76
6.4. Advanced programming
Note
Press and hold + for 5 seconds to access advance programming. A "P" symbol is
displayed on the bottom left of screen.
The 740/760 features an advanced programming level that allows the installing dealer to make
changes to the controller for more demanding applications. The homeowner/end user should never
have to access this level.
The advanced programming menus include:
•P1 = Time of day;
P2 = Day of week;
P3 = Time of regeneration;
P4 = Number of days between regeneration (99 day calendar override);
P5 = (740 only);
P6 = Amount of brine used per regeneration or filter backwash time (1-99 minutes);
P7* = System capacity;
P8 = Hardness;
P9** = Units of measurement;
•P10** = Clock mode.
* Calculated by software.
** Pre-selected by World model (i.e. 230 Vac, 50 Hz, metrics unit).