EasyManua.ls Logo

Pentair Evolio 255 Series - Page 41

Pentair Evolio 255 Series
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer manual Evolio 255 740-760 - Programming
Ref. MKT-IM-037 / D - 25.10.2021 41 / 90
Press Initial
display
Evolio 255
10
Evolio 255
15
Range Parameter
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
1 for Monday - 7 for
Sunday
1 - 7 Day of week
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
02:00 Time of regeneration -
set up as per your
requirement
00:00
23:59
Regen time
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
0
Adapt to local norms 0 - 99 Calendar
override
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
S L S H L S H L, S, H Salt
dosage
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
Calculated
upon
previous
settings*
0.3 0.5 0.7 0.5 0.9 1.2 0.1 - 14 Capacity in
kg as CaCO
3
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
100 Input value: (inlet
hardness – residual
hardness)**
30 - 2000 Hardness in
mg/L CaCO
3
or ppm
Press Initial
display
Evolio 255
20
Evolio 255
30
Range Parameter
UP and DOWN arrow to scroll
through values, press SET to
confirm.
--- 10 15 5 - 80 Volume of
resin in L
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
--:-- Set up actual time of
day.
00:00
23:59
Time of day
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
1 for Monday - 7 for
Sunday
1 - 7 Day of week
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
02:00 Time of regeneration -
set up as per your
requirement
00:00
23:59
Regen time

Table of Contents