Loading...
Installer manual Evolio 255 740-760 - Programming
42 / 90 Ref. MKT-IM-037 / D - 25.10.2021
Press Initial
display
Evolio 255
20
Evolio 255
30
Range Parameter
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
0
Adapt to local norms 0 - 99 Calendar
override
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
S L S H L S H L, S, H Salt
dosage
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
Calculated
upon
previous
settings*
0.7 1.4 1.6 1.0 1.9 2.3 0.1 - 14 Capacity in
kg as CaCO
3
Press SET to select, display blink,
press UP/DOWN arrows to
program actual time of day, press
SET to confirm.
100 Input value: (inlet
hardness – residual
hardness)**
30 - 2000 Hardness in
mg/L CaCO
3
or ppm
* Override if necessary as per indicated in this table.
** Make sure to set up residual hardness as per value used for programming.
5.4 Basic programming
5.4.1 Program system size
Set the resin volume in liters.
1. Use and to scroll though resin volume
choices.
2. Choose the volume to your system model (10, 15, 20
or 30 L).
3. Press to validate the resin volume selected and
advance to the next parameter using or .
4. If an incorrect setting is programmed, see Resetting
the controller [
Page47]
5.4.2 Time setting and winter time - summer time change
Set the current time.
1. Press when the time of the day is displayed.
ð Time flashes.
2. Adjust displayed time with and .
3. Press to validate the selection and advance to the
next parameter using or .

Table of Contents