SunTouch
®
Control System Installation and User’s Guide
Pump Menu (12/14) (Continued)
IntelliFlo
®
VS pump (Continued)
From the IntelliFlo VS Pump menu you can assign an auxiliary circuits to control four different pump speeds.
The pump speed can be adjusted from 400 to 3450 RPM in increments of 10 RPM. For more information
about the IntelliFlo VS Pump, refer to the IntelliFlo VS Pump Installation and Users Guide (P/N 357269).
To assign up eight (8) pump speeds and circuits for the IntelliFlo VS3050 Pump:
Menu button: Select the Pumps 12/14 menu.
Right button: Press the button to view the type of pump to select.
Up/Down buttons: Select IntelliFlo VS. Press Right button again to select.
Press Up/Down buttons to view the pump parameters menus: SPEEDS, PRIMING
or STATUS. Press Right button to select. Press the Right button again to ASSIGN
SPEEDS (RPM) setting. Press Up/Down buttons set the pump speed. Pump speeds
can be set from 400 to 3450 RPM in increments of 10 RPM. The default speed for
each circuit is the same as the four speed buttons on the IntelliFlo VS Pump control
panel. The preset speed which corresponds to each of the four buttons on the pump
are: 1 button 750 RPM, 2 button 1500 RPM, 3 button 2350 RPM, and 4 button 3110
RPM.
Press Right button to ASSIGN CIRCUIT for the pump. Press Up/Down buttons
to view the circuits for the rst of eight pump circuits: [NONE, SPA, POOL,
AUX
1,
AUX 2, AUX 3, FEATURE 1 - 4, SOLAR, HEATER, FREEZE, POOL/SPA, and
SOLAR/HT (solar/heater)]. Press Right button to select the circuit. Note: Selecting
“Pool/Spa” or “Solar/HT” combines several circuits into the same pump speed
for pool and spa or for solar and heater combination systems. Normally this would
require programming two separate pump speeds for each function. Using one of these
selections, free-up one of the four pump speed for other uses.
Right button: Press this button to continue to assign pump SPEEDS and
CIRCUITS. You can assign up to eight (8) pump speeds and circuits.
When nished assigning speeds and circuits, press the Right button until SPEEDS
is displayed, then press the Up/Down buttons and select PRIMING. Press Right
button to select Priming Params Time. Press the Up/Down buttons to set the
priming time (0 to 10 minutes). When nished, Press Right button to select Priming
Params Speed. Press the Up/Down buttons to set the priming speed (4000 - 3450
RPM). To select STATUS, press the Right button three (3) time, then press the Up/
Down button to select STATUS. Press the Right button to view the current RPMs
and operating Watts. Press the button again to view the current pump communication
status.
Left button: Press the Left button to return to the main status screen.
Assign Speeds
1 - RPM: 3450
Main Menu 12/14
Pumps
Pumps Parameters
Menu: SPEEDS
Priming Params
Time: 5
Circuit Setup
1 - [ SPA ]
Status: NORMAL
RPM: 1500 75 W
Pump Type
[INTELLIFLO VS ]
Pumps Parameters
Menu: PRIMING
Priming Params
Speed: 1000
Pumps Parameters
Menu: STATUS