35
SunTouch
®
Control System Installation and User’s Guide
Pump Menu (12/14) (Continued)
IntelliFlo
®
VSF+SVRS Pump
From the IntelliFlo
®
VSF+SVRS Pump menu you can assign circuits to control the pump ow rate (GPM/
RMP), priming, also lter, backwashing, vacuum functions and view the current pump status. For more
information about the IntelliFlo VS Pump, refer to the IntelliFlo VF Pump Installation and User’s Guide (P/N
350075).
To assign up eight (8) pump speeds and circuits for the IntelliFlo VS pump:
Menu button: Select the Pumps 12/14 menu.
Right button: Press the button to view the type of pump to select.
Up/Down buttons: Select IntelliFlo VF them press Right button again to select.
Press Up/Down buttons to view the Pump Parameters menus: CIRC. SETUP, and
STATUS. Press Right button to choose one of the parameters.
CIRCUIT SETUP: Press Right button to assign a circuit to the pump. Press Up/
Down buttons to view the circuits for the rst of eight (8) pump circuits: [NONE,
SPA, POOL, AUX 1, AUX 2, AUX 3, FEATURE 1-4, SOLAR, HEATER, POOL
HEAT, SPA HEAT, FREEZE, POOL/SPA, and SOLAR/HT (solar/heater)].
GPM/RPM Mode: Press the Right button to set the GPM and RPM pump speed.
Press Up/Down button to toggle between RPM and GPM/PSI.
The Assign Flows screen displays. Press Up/Down buttons to set the pump ow
rate from 15 - 130 GPM. The default ow rate is 30 GPM. The preset speed for each
button is: Speed 1 button 1100 RPM (30 GPM), Speed 2 button 1500 RPM, Speed
3 button 2350 RPM, and Speed 4 button 3110 RPM.
Press the Right button again to set the PSI setting. Press Up/Down buttons to set
pump pressure setting from 1 to 30 PSI.
Press Right button to select the circuit. Note: Selecting “Pool/Spa” or
“Solar/HT” combines several circuits into the same pump speed for pool and spa or
for solar and heater combination systems. Normally this would require programming
two separate pump speeds for each function. Using one of these selections, free-up
one of the four pump speed for other uses.
Press Right button to continue to assign pump FILT. CIRC. and CIRCUITS. You
can assign up to eight (8) pump speeds and circuits.
When nished assigning pump ow rate and circuits, press the Right button until
FLOWS is displayed, then press the Up/Down buttons and select FILTER.
Press Right button to select Assign Flows. Press the Up/Down buttons to set the
ow rate from 15-150 GPM.
Press Right button to select Assign PSI. Press the Up/Down buttons to set the
pressure rate from 1-30 PSI.
Left button: Press the Left button to return to the main status screen.
Assign Flows
1 - GPM: 80
Main Menu 12/14
Pumps
Circuit Setup
1 - [ POOL ]
Pump Type
[INTELLIFLO VF ]
Pumps Parameters
Menu: CIRC. SETUP
GPM/RPM Mode
GPM (RPM)
Assign Circuit
1 - [SPA ]
Assign Speeds
1 - RPM: 7710
Assign Flows
1 - GPM: PSI
Assign PSI
1 - PSI: DSBL