Control System Installation and User’s Guide
Temperature vs. Resistance Data
The SunTouch
®
Control System use 10k Ohm thermistor sensors. When the solar sensor is disconnected
from the SunTouch Control System, the sensor will read 10k Ohm at 77º F (25ºC). Refer to the
following table for the resistance at other temperatures. An accurate reading should give a temperature
setting that is accurate
Temperature Resistance Temperature Resistance
°C °F Ohm °C °F Ohm
-26 -15 139,300 16 60 15,310
-25 -13 130,300 18 65 13,480
-23 -10 118,000 21 70 11,880
-21 -5 100,200 24 75 10,500
-20 -4 97,000 25 25 77 10,000
-18 0 85,350 27 27 80 9,298
-15 5 72,910 29 29 85 8,250
-12 10 62,480 30 30 86 8,056
-9 15 53,640 32 32 90 7,331
-10 14 55,300 35 35 95 6,530
-7 20 46,230 38 38 100 5,826
-5 23 42,300 40 40 104 5,326
-4 25 39,910 41 41 105 5,209
-1 30 34,560 43 43 110 4,663
0 32 32,600 45 45 113 4,367
2 35 30,000 49 49 120 3,757
4.7 40 26,100 50 50 122 3,602
5 41 25,400 52 52 125 3,381
7 45 22,760 54 54 130 3,047
10 50 19,900 55 55 131 2,985
13 55 17,440 57 57 135 2,750
15 59 15,700