32
SunTouch
®
Control System Installation and User’s Guide
Pump Menu (12/14) (Continued)
IntelliFlo
®
VF Pump
From the IntelliFlo
®
VF Pump menu you can assign circuits to control the pump ow rate (GPM), priming,
also lter, backwashing, vacuum functions and view the current pump status. For more information about the
IntelliFlo VS Pump, refer to the IntelliFlo VF Pump Installation and Users Guide (P/N 350075).
To assign up eight (8) pump speeds and circuits for the IntelliFlo VS Pump:
Menu button: Select the Pumps 12/14 menu.
Right button: Press the button to view the type of pump to select.
Up/Down buttons: Select IntelliFlo VF them press Right button again to select.
Press Up/Down buttons to view the Pump Parameters menus: CIRC. SETUP,
FILT. CIRC., FILTER, PRIMING, BACKWASH, VACUUM and STATUS. Press
Right button to choose one of the parameters.
Press the Right button again to ASSIGN FLOWS (GPM) setting.
Press Up/Down buttons set the pump ow rate (15 - 130 GPM).
Press Right button to CIRCUIT SETUP for the pump. Press Up/Down buttons to
view the circuits for the rst of eight (8) pump circuits: [NONE, SPA, POOL, AUX
1, AUX 2, AUX 3, FEATURE 1-4, SOLAR, HEATER, POOL HEAT, SPA HEAT,
FREEZE, POOL/SPA, and SOLAR/HT (solar/heater)].
Press Right button to select the circuit. Note: Selecting “Pool/Spa” or
“Solar/HT” combines several circuits into the same pump speed for pool and spa or
for solar and heater combination systems. Normally this would require programming
two separate pump speeds for each function. Using one of these selections, free-up
one of the four pump speed for other uses.
Press Right button to continue to assign pump FILT. CIRC. and CIRCUITS. You
can assign up to eight (8) pump speeds and circuits.
When nished assigning pump ow rate and circuits, press the Right button until
FLOWS is displayed, then press the Up/Down buttons and select FILTER.
Press Right button to select Filter Params Time. Press the Up/Down buttons to set
the Filter Size (1000 to 255000 gallons).
Press Right button to select Filter Params Manual Filter. Press the Up/Down
buttons to set the Filter Size (15 - 130).
When nished, Press Right button to select Filter Params Turns. Press the Up/
Down buttons to set the number of pool cycle turns (1-4).
When nished assigning lter parameters, press the Right button until FLOWS is
displayed, then press the Up/Down buttons and select FILTER
.
Press Right button to select Filter Params Time. Press the Up/Down buttons to set
the Filter Size (1000 to 255000 gallons).
Press Right button to select Filter Params Manual Filter. Press the Up/Down
buttons to set the Filter Size (15 - 130).
Assign Flows
1 - GPM: 80
Main Menu 12/14
Pumps
Circuit Setup
1 - [ POOL ]
Pump Type
[INTELLIFLO VF ]
Filter Params
Size: 25000
Pumps Parameters
Menu: FILTER
Filter Params
Turns: 2
Filter Params
Man Filt: 30
Pumps Parameters
Menu: CIRC. SETUP