34
SunTouch
®
Control System Installation and User’s Guide
Pump Menu (12/14) (Continued)
IntelliFlo
®
VF Pump
When nished, Press Right button three times until FILTER is displayed.
Press the Up/Down buttons to select PRIMING.
Press the Right button to select Priming Params: Max Flow.
Press the Up/Down buttons to select the maximum ow GPM rate (15-130).
Press the Right button to select the Max Time, press the Up/Down buttons to select
the maximum time from 1 to 15 minutes.
Press the Right button to select the Sys Time, press the Up/Down buttons to select
the maximum time from 1 to 15 minutes.
When nished assigning lter parameters, press the Right button until PRIMING is
displayed, then press the Up/Down buttons to select BACKWASH.
Press Right button to select Backwash Params Clean Filt:
Press the Up/Down buttons to set the lter clean time (1-50 minutes).
Press Right button to select Flow GPM. Press the Up/Down buttons to set the ow
rate (15-130 GPM).
Press Right button to select Duration. Press the Up/Down buttons to set the
duration (1-60 minutes).
Press Right button to select Rinse Time. Press the Up/Down buttons to set the rinse
time (1-60 minutes).
When nished assigning lter parameters, press the Right button until
BACKWASH is displayed, then press the Up/Down buttons to select VACUUM.
Press Right button to select Vacuum Params Flow (gpm): Press the Up/Down
buttons to set the gpm ow rate (15-130 GPM).
Press Right button to select Flow GPM. Press the Up/Down buttons to set the ow
rate (15-130 GPM).
Press Right button to select Time (min). Press the Up/Down buttons to set the
vacuum time (1-600 minutes).
Press Right button to select Rinse Time. Press the Up/Down buttons to set the rinse
time (1-60 minutes).
When nished assigning vacuum parameters, press the Right button until VACUUM
is displayed, then press the Up/Down buttons to select STATUS.
Press Right button to view the current RPM, WATTS and GPM status.
Press the Right button again to view the Filter and pump operation status.
When nished assigning vacuum parameters, press the Right button until STATUS
is displayed, then press the Up/Down buttons to select FILT. CIRC.
Press Right button to view the lter circuits. Press the Up/Down buttons to select
the circuit: (NONE, SPA, POOL, AUX 1, AUX 2, AUX 3).
Left button: Press the Left button to return to the main status screen.
Backwash Params
Clean Filt: 10
Pumps Parameters
Menu: BACKWASH
Priming Params
Flow GPM: 60
Priming Params
Duration: 5
Priming Params
Rinse Time: 5
Vacuum Params
Flow (gpm): 65
Pumps Parameters
Menu: VACUUM
Vacuum Params
Time (min): 30
Filter: 0
Status: NORMAL
RPM: 1500 75 W
GPM: 50
Pumps Parameters
Menu: STATUS
Filter Circuit
[ POOL ]
Pumps Parameters
Menu: FILT. CIRC
Priming Params
Max Flow: 55
Pumps Parameters
Menu: PRIMING
Priming Params
Max Time: 5
Priming Params
Sys Time: 1