2023-11
104
VisuNet FLX System
Maintenance, Cleaning and Disposal
8 Maintenance, Cleaning and Disposal
All VisuNet FLX models perform a degree of thermal management to avoid overheating under
heavy load. The VisuNet FLX devices have an internal temperature sensor, which software on
the GPU polls to ensure that temperatures do not exceed a predefined limit.
8.1 Frequency Management
The following maintenance intervals must be observed
8.2 Maintenance
Note
Operating temperature has influence on the VisuNet FLX lifetime.
Caution!
Suitability for Zone 2/22 and DIV 2!
Substitution of components may compromise suitability for Zone 2/22 and DIV 2.
Caution!
Use only approved spare parts.
The installation of spare parts not intended for the VisuNet FLX may damage the device,
machine or system. The warranty is void if you install spare parts that are not permitted.
Only original service parts from P+F are allowed to be used.
Interval Location Activity
Daily Overall device Visually inspect for loose
objects and visible damage
Monthly Fixing screws Check that they are seated
securely; tighten as necessary
Optional, if installed
Daily Emergency stop button Check that it functions cor-
rectly