EasyManua.ls Logo

Perkins 404C-22T - Cold Weather Operation; Cold Weather Operation Factors; Hints for Cold Weather Operation

Perkins 404C-22T
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
26 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green
400 Series
To inspect - valve stem and thickness of valve head Operation 3-14
Use a micrometer to check the valve stem diameters at positions 1, 2 and 3, if less than the service limit, renew.
Check the valve stem for wear or damage, if outside the service limit, renew.
Inlet valve
Exhaust valve
Valve head thickness
If the valve head thickness (4) is less than the service limit, renew the valve.
Engine
Diameter mm (in)
Standard Service limit
All models 6,955 - 6,970 (0.27382 - 0.27441) 6,89 (0.271)
Engine
Diameter mm (in)
Standard Service limit
All models 6,940 - 6,950 (0.27323 - 0.27362) 6,84 (0.269)
Engine
Thickness mm (in)
Standard Service limit
All models 0,925 - 1,075 (0.03642 - 0.04232) 0,5 (0.020)
H1047
1
1
2
2
3
3
4

Table of Contents

Other manuals for Perkins 404C-22T

Related product manuals