PROFESSIONAL INSTALLER – COMPLIANCE
US and Canada Power Limits
Mode: SISO: Only One Port Active
MIMO (2x2): 2 Ports Active
Power Setting / Port
MIMO (3x3): All 3 Ports Active
Power Setting / Port
CHANNEL:
Max. Power Setting
Approved (dBm)
Max. EIRP
(dBm)
Max. Power Setting
Approved (dBm)
Max. EIRP
(dBm)
Max. Power Setting
Approved (dBm)
Max. EIRP
(dBm)
1 28 32 26 31 24.5 31
2 30 35 26 32 24.5 31
3 30 36 26 32 24.5 31
4 30 36 26 32 24.5 31
5 30 36 26 32 24.5 31
6 30 36 26 32 24.5 31
7 30 36 26 32 24.5 31
8 30 36 26 32 24.5 31
9 30 36 26 32 24.5 31
10 30 33 26 32 24.5 31
11 29 32 26 31 24.5 31