© 2010 - 2018 Persistent Systems, LLC – All Rights Reserved
145
PROFESSIONAL INSTALLER – COMPLIANCE
Minimum Safe Distance (MSD)
Antenna Gain (dBi)
*Occupational Expo-
sure Distance (cm)
Non Occupational Ex-
posure Distance (cm)
Dipole (Omnidirec-
tional)
2.1 7.0 20.0
3.5 7.0 20.0
4.0 8.0 20.0
7.4 **11.0 **25
In addressing the MSD for operation of the RF-2100 S-Band (2200 MHz – 2500 MHz) radio module with FCC ID
2AG3J-RF2100 and IC ID 20968-RF2100 and the RF-5100 Upper C-Band (5100 MHz – 6000 MHz) radio module with
FCC ID 2AG3J-RF5100 and IC ID 20968-RF5100, the applicable Maximum Permissible Exposure (MPE) limits were
obtained IAW the FCC rules for radio frequency radiation exposure limits under
FCC Title 47, Chapter 1 Subpart 1
Article 1.1310 and Industrial Canada RSS-102, Section 2.6
.
En abordant la MSD pour le fonctionnement des RF-2100 S-Band (2200 MHz - 2500 MHz) module radio avec FCC
ID 2AG3J-RF2100 et IC ID 20968-RF2100 et RF-5100 Upper C-Band (5100 MHz – 6000 MHz) avec FCC ID 2AG3J-
RF5100 et IC ID 20968-RF5100, l’exposition maximale admissible applicable (MPE) limites ont été obtenus con-
formément à la FCC règles pour les limites d’exposition aux radiations de fréquences radio sous FCC Titre 47,
Chapitre 1 partie 1 article 1,1310 et industriel Canada RSS-102, Section 2.6.
For compliance information, contact Persistent Systems’ Quality Management Department.
Pour plus d’informations de conformité, le service de qualité contact Persistent Systems.
(212)-561-5895
support@persistentsystems.com