6.2 Temperature of welding seal limitaton blades (if installed)
- To enter the temperature value to be reached by the blades, press key:
The display shows:
BLADES TEMP.
40.0 38.5
<ESC>
- The value indicated on the left is the one entered by the operator, the value displayed on the
right is the one read in real time by the thermocouple.
- Use the keyboard to enter the desired value and press ESC to exit and confirm the entered
value.
- The controller accepts temperatures up to 60 °C, should a higher value be entered, the
controller sends an error.
- The electronic controller activates the cartridge resistors with the aim to reach the entered
temperature and adjusting the power keeps it within the tolerance limits entered in the
parameters.
- The default alarm level is 5°C, should the temperature read by thermocouple be lower or
higher than this level, the controller shows the message “WAIT FOR TEMP. OK”.
.
6.3 Timer for warming-up
- To enter the value of the heating timer press key:
The display shows:
HEATING TIMER
15.0
<ESC>
- The value indicated on the left is the one entered by the operator (in seconds).
- Use the keyboard to enter the desired value and press ESC to exit and confirm the entered
value.