Revision: 3.0.3
PDU
Address
Register
$0000 40001 Flow/s -
$0001 40002 Flow/s -
$0002 40003 Flow/m -
$0003 40004 Flow/m-
$0004 40005 Flow/h -
$0005 40006 Flow/h - high
$0006 40007 Velocity –
$0007 40008 Velocity –
$0008 40009 Positive total –
$0009 40010 Positive total –
$000A 40011 Positive total –
$000B 40012
Negative total—
$000C 40013
Negative total—
$000D 40014
Negative total—
$000E 40015
Net total—
$000F 40016
Net total-
$0010 40017
Net total—
$0016 40023 Up signal int –
$0017 40024 Up signal int –
$0018 40025 Down signal int
$0019 40026 Down signal int
$001A 40027 Quality
$001B 40028
4~
word
$001C 40029
4~
word
$001D 40030 Error code –
$001E 40031 Error code –
$001F 40032 Error code –
$003B 40060 Velocity unit –
$003C 40061 Velocity unit –
D116
Series Ultrasonic Flowmeter
Type
No.
registers*
32 bits real 2
32 bits real 2
32 bits real 2
32 bits real 2
32 bits uint. 2
16 bits int. 1
32 bits int. 2
16 bits int. 1
32 bits int. 2
16 bits int. 1
32 bits real 2
low word 32 bits real 2
high word
16 bits int. 1
-low
32 bits real 2
-high
String 3
3,4
String 2
Series Ultrasonic Flowmeter
Page 45 of 53
Remark
0~99.9
0~99.9
0~99
Unit: mA
Refer to "Error
Analysis" for
detailed codes
meanings.
m/s only