Page #24 background imageLoading...
Page #24 background image
Revision: 3.0.3
Inlet Water Temp / Outlet Water Temp / Delta
Temp
Display
Inlet Water Temperature, Outlet Water
Temperature and Delta Temperature.
System Error Codes
Display the Working Condition and the S
ystem
C
odes. More than one error code can occur at the
same time.
The explanations of error codes and detailed
resolution methods can be found in "
Error Diagnoses
POS Flow Today
Display POS Flow Today.
Pipe Outer Diameter
Enter the pipe outside diameter
or enter the pipe
circumference in Window M10.
The pipe outside
diameter must range from 10mm to 60
00mm.
Note: Enter either pipe outside diameter or pipe
circumference.
Pipe wall thickness
Pipe Material
Enter pipe material.
The following options are
available (by
buttons or numerical keys):
0. Carbon Steel 5. PVC
1. Stainless Steel 6. Aluminum
2. Cast Iron 7. Asbestos
3. Ductile Iron 8. Fiber Glass-
Epoxy
4. Copper
Menu 0 7
Menu 0 8
Menu 0 9
Menu
1 1
Menu
1
2
Menu
1
4
^
^
D116
Series Ultrasonic Flowmeter
Inlet Water Temp / Outlet Water Temp / Delta
Inlet Water Temperature, Outlet Water
ystem
Error
odes. More than one error code can occur at the
The explanations of error codes and detailed
Error Diagnoses
"
or enter the pipe
The pipe outside
00mm.
Note: Enter either pipe outside diameter or pipe
The following options are
buttons or numerical keys):
Epoxy
In-Out-Delta C
6.21 8.21 -
2.00
*R
--------------
SystemNormal
POS Flow Today M09
0.458 m3
Pipe Outer Diameter
50
mm
Pipe Wall Thickness
6.00 mm
Pipe Material [14
0. Carbon Steel
Series Ultrasonic Flowmeter
Page 24 of 53
2.00
--------------
POS Flow Today M09
0.458 m3
Pipe Outer Diameter
mm
Pipe Wall Thickness
Pipe Material [14

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PFlow Industries D116 and is the answer not in the manual?

PFlow Industries D116 Specifications

General IconGeneral
BrandPFlow Industries
ModelD116
CategoryMeasuring Instruments
LanguageEnglish