Revision: 3.0.3
Transducer Type
0. Standard(clamp-
on type transducer
1. Type-45B(W211
type insertion transducer
Transducer Mounting
Four mounting methods are available:
0. V
1. Z
2. N
Transducer Spacing
The operator must mount the transducer
according to
the transducer spacing displayed (be sure that the
transducer spacing must be measured precisely during
installation). The system will display the data
automatically after the pipe parameter had been
entered.
Initial Parameter Setups and Save
Load and save the parameters. 18 different sets of
setup conditions/groups are available to load and save
by three methods
0. Entry to Save
1. Entry to Load
2. To Browse
Select "Entry to Save", press
. An ID code and the
original parameters are displayed in the window. Press
UP or DOWN ARROW to move the ID code, then
press the
key again to save the current
parameter in the current ID room. When selecting
"Entry to Load"
, press ENT, and the system wi
and calculate the parameters automatically and display
the transducer mounting spacing in Window M25.
Cross-sectional Area
Menu 2
3
Menu 2 4
Menu 2 5
Menu 2 6
Enter
Enter
Menu 2 7
D116
Series Ultrasonic Flowmeter
on type transducer
)
type insertion transducer
)
according to
the transducer spacing displayed (be sure that the
transducer spacing must be measured precisely during
installation). The system will display the data
automatically after the pipe parameter had been
Load and save the parameters. 18 different sets of
setup conditions/groups are available to load and save
. An ID code and the
original parameters are displayed in the window. Press
UP or DOWN ARROW to move the ID code, then
key again to save the current
parameter in the current ID room. When selecting
, press ENT, and the system wi
ll read
and calculate the parameters automatically and display
the transducer mounting spacing in Window M25.
Transducer Mounting
0. V
Transducer Spacing
159.86
mm
Parameter Setups
Entry
to SAVE
Cross-
sectional Area
31415.9 mm2
Series Ultrasonic Flowmeter
Page 25 of 53
Transducer Mounting
Transducer Spacing
mm
Parameter Setups
to SAVE
sectional Area
31415.9 mm2