15705-011 | Rev  | 2022-03-01 | e-mail csd@pow.com Section 11 | 3
Section 11 | SEW Eurodrive Motor
Maintenance and Troubleshooting
www.pflow.com
P 414 352 9000
F 414 352 9002
6720 N. Teutonia Ave.
Milwaukee, WI 53209
Air Gap
Values
1) The specied values are nominal values that were determined during
rating operation. The actual braking work that can be reached before
maintenance may vary depending on the actual load during operation.
2) When checking the working air gap, note that parallelism tolerance on
the brake disk may give rise to deviations of +/-0.15 mm aer a test run.
3) The brake lining carrier of the BE03 can not be replaced. Replace the
brake when the maximum working air gap is reached.