 | Section 11 15705-011 | Rev  | 2022-03-01 | e-mail csd@pow.com
Section 11 | SEW Eurodrive Motor
Maintenance and Troubleshooting
www.pflow.com
P 414 352 9000
F 414 352 9002
6720 N. Teutonia Ave.
Milwaukee, WI 53209
Feeler Gauge Positions
Figure 11-2
Adjust the
Air Gap (if
needed)
Adjusting Nuts
Figure 11-3
Any adjustment to the air gap will also aect
the play in the manual release.
Tighten or loosen the adjusting nuts equally
and evenly around the brake as needed.
Continue to measure the air gap with a feeler
gauge at
three dierent positions around the
brake
between the stationary disc and the
coil until the minimal air gap clearance is
reached. See Figure 11-3.