EasyManua.ls Logo

Philips 3000 V2 - Water Filter; Milk Solution

Philips 3000 V2
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PHILIPS 3000 V2 03 OPERATING LOGIC
6/6
Bypass
3.9. Waterlter
Function:
Reduced limescale deposits which take longer to form.
Improved water quality.
Improved taste due to the ideal water hardness.
Lifespan/descalingperformance:
- 10 ° dH
60 litres
2 months
To achieve the best possible operating mode consistency
over the total life span, the water is channelled using
a 3-stage bypass (A, B, C) depending on the degree of
hardness. See small image.
1
2
3
1) Steam input
2)Milk container
3) Cappuccinatore
Steam
Milk
The milk is heated by the steam and taken
towards the emulsion chamber where it is
mixed with air and transformed into foam.
The steam passes through the
pipe creating a sucking eect
that pulls the milk upwards.
3.10.MilkSolution
Descalingcyclefrequency
Hard-
ness
Waterhardness Withoutwaterlter Withwaterlter
1 Soft (up to 7°dH) 240 litres (480,000 pulses) 480 litres (960,000 pulses)
2 Medium (7° - 14°dH) 120 litres (240,000 pulses) 240 litres (480,000 pulses)
3 Hard (15° - 21°dH) 60 litres (120,000 pulses) 120 litres (240,000 pulses)
4 Very hard (over 21°dH) 30 litres (60,000 pulses) 60 litres (120,000 pulses)
Each litre of water corresponds to approximately 1925 pulses.

Related product manuals