PHILIPS 3000 V2 04 SERVICE MODE
2/9
TEST MODE Level0
Pressing button Stand-By
TEST MODE Level1
Pressing button Stand-By
TEST MODE Level2
Pressing button Stand-By
TEST MODE Level3
Pressing button Stand-By
TEST MODE Level4
Pressing button Stand-By
TEST MODE Level5
At the start up all loads are turned o. The software allow to have only one load active at the same
time.
Pressing button Stand-By
Level 2: The machine can test other input signal:
a) Microswitch door closed/opened
b) Microswitch present of the brewing unit
c) Water Tank sensor
Level 3: The machine can test the loads in low voltage:
a) Brew Unit movement upward and downward (24V DC)
Level 4: The machine can test the loads:
a) Pump (230V AC)
b) DC Solenoid Valve @24V.
c) Flow Meter
Level 5: The machine can test:
a) Heater (100-120-230V AC)
b) Grinder (140-170-320V DC)
c) Grinder sensor
The user can switch the level by pressing the Button Stand-By, the machine shows the level of the
test:
a) Level 1 : Led Espresso ON (G), Led Stand-by ON (R)
b) Level 2 : Led Espresso ON (G), Led Descale ON (O)
c) Level 3 : Led Espresso ON (G), Led Descale ON (O), Led Calc-Clean ON (O)
d) Level 4 : Led Espresso ON (G), Led Descale ON (O), Led Calc-Clean ON (O), Led Rinsing ON(O)
e) Level 5 : Led Espresso ON (G), Led Descale ON (O), Led Calc-Clean ON (O), Led Rinsing ON(O),
Led Coee ON (G).
Legend:
(O) = Orange
(G) = Green
(R) = Red