1- Position the wall bracket so that the screen of the monitor is approximately 1.60m above the oor.
2- Mark the location of the holes by placing the bracket on the wall.
Note: if you prefer, you can use the 2holes in the centre of the bracket, which are designed to
match a 68mm wall recess-mount housing.
3- Drill.
4- Use pegs adapted to the type of bracket (those supplied are suitable for solid walls).
5- Attach the wall bracket.
6- Connect the two intercom panel wires and the two power supply wires following the wiring
diagram.
Note:
- On BUS A and BUS B wires, the polarity is irrelevant.
- The polarity of the power supply wires is indicated on the end of the wires; there is a “+” symbol
for 24VDC and a “-” symbol for GND on the wires.
7- Position the monitor on the wall bracket.
Warning: during this step, do not connect the power supply to the 230VAC.
5.3. Installing the intercom panel
Warning:
-The product must not be connected to the power supply before wiring has been completed.
- The locking screw must not be removed. To remove the front of the intercom panel, unscrew the
screw using the tool provided. The screw will go in instead of out when you unscrew it: this is normal.