www.phocos.com 27 | P a g e
UPS (Default) Accepted AC input voltagerange
from 170 ~ 280 Vac for 230 Vac
models, 90 ~ 140Vac for 120Vac
models.
05
Battery type
Settings menus 26, 27and 29
can only be modified if “User-
definedis selected here.
Please visit www.phocos.com
for a current list of (Lithium)
batteries supportedand their
specific s ettings guides.
CAUTION: Do not use
inverter communication
cables supplied with your
batteries unless instructed
by Phocos guides as this
may damage the PSW-H
and/or the battery!
AGM (Default) Flooded
User-defined Battery charging voltages and low
voltage disconne ct (LVD) can be
manually defined in settings menu
26, 27 and 29.
Pylontech battery For use with Pylontech Lithium
batteries. Ensure the battery
management syst em (BMS)
communication is connect ed.
WeCo batte ry For use withWeCo Lithium
batteries. Ensure the battery
management syst em (BMS)
communication is connect ed.
BYD batte ry For use with BYD Lithium batteries.
Ensure the battery management
system (BMS) communicationis
connected.
RS-48 5 (MODBUS RTU) battery For use with Lithium batteries
using the Phocos MODBUS RTU
communication protocol. Ensure
the battery manag ementsystem
(BMS) communication is
connected.
06
Automatic restart if an AC
output overload occurs
Restart disabled(Default) Restart enabled
07
Automatic restart when over-
temperature occurs
Restart disabled(Default) Restart enabled

Other manuals for Phocos Any-Grid Series