- If the open-circuit voltage is higher or equal to 12.6V, the battery is charged adequately. Slightly shake
or tilt the battery to eliminate any air bubbles formed during recharging.
- Check the electrolyte levels again, fill them with distilled water up to the upper level line if necessary,
clean battery properly, close each single cell cap tightly and install it on the vehicle.
- If the voltage indicated is low, charge the battery another 4-6 hours in the way described above.
Note: With the battery charger drw. 020334Y, it is possible to check the battery charge level with the
Check function. The value indicated on the display must be higher than the value indicated on the chart;
otherwise, recharge the battery again in the same way indicated above.
Electrical system B 125-250