EXTERNAL THERMOSTAT
Action Description Display
Stove operation can be regulated by any kind of external room thermostat
connected to the electronic board.
To connect the thermostat, see paragraph “INSTALLING THE EXTERNAL
ROOM THERMOSTAT”.
Operation of the external thermostat depends on the stove temperature
setting.
•If the set stove temperature is less than the room temperature, the
external thermostat prevails. (It is advisable to set a minimum value of
44°F / (7°C) for the stove).
•If the set stove temperature is more than the room temperature, the
internal stove thermostat prevails. The external thermostat is disabled.
a The room sensor must be connected. If the room sensor is not
connected the appliance does not modulate the power and
operates to user settings.
DT2040059-06
DT2012309-00
6.5 TROUbLEShOOTING
A list of situations that could occur and instructions on what to do is given below.
FAILED IGNITION
Action Description Display
If the readout NO LIT appears on the display during the startup stage and
the buzzer activates (if set), it means that the sensor installed on the ue
gas outlet detects no temperature rise (sign that the combustion process
has not been triggered) or the pellet hopper is empty. The stove goes into
the alarm status.
1
!
NO
LIT
1 2:00 73F
DT2040056-06