by the user, the stove automatically goes to power level 1 (readout “OK” on the display).
If the room temperature continues to rise with operation at power level 1 up to the value set on the STOP function (e.g. +4 °F / +2 °C compared to
the programmed temperature), the stove shuts down and goes into the stand-by mode.
When the room temperature measured by the room sensor, the remote control or the external thermostat drops to the temperature value set by the
user on the START function (e.g. -6 °F / -3 °C compared to the programmed temperature), the stoves starts a new ignition phase and goes back to
the power level previously set by the user.
a The stove only restarts when the temperatures measured on the actual stove allow its use in all safety.
If the STOP and OFF functions are enabled, upon reaching the programmed room temperature, the stove will operate in the conventional way by
going to power level 1 without shutting down.
Likewise with the START and OFF enabled the stove does not start the startup/ignition phase after automatic shutdown and will remain off.
ENERGY SAVING
Function Action Display
Select the ENERGY
SAVING menu
Press the MENU key, then using the SELECT MENU key select the ENERGY
SAVING function and conrm by pressing the SET key.
1
Select the value to
be set for shutdown
temperature
Press the SELECT MENU key and then select the temperature set point 2,
4 or 6 °F (1, 2 or 3 °C) or disable the function by selecting OFF.
Conrm by pressing the SET key.
2F
Select the value to
be set for ignition
temperature
Press the SELECT MENU key and then select the temperature set point 2,
4 or 6 °F (1, 2 or 3 °C) or disable the function by selecting OFF.
Conrm by pressing the SET key.
After conrmation using the SET key, the readout FUNTION ENABLED is
displayed and the readout ENS (ENERGY SAVING) appears on the main
display.
Upon reaching the temperature set in the STOP function, the stove starts
the shutdown stage.
The readout ENERGY SAVING OK appears on the display.