OPERATING MANUAL PSEN op4F/H-A series
T
he table below states the operating ranges based on the number of mirrors used.
Number
of mirrors
Operating range
(14 mm)
Operating range
(30 mm)
1
5.1 m
16.5 m
2
4.3 m
13.7 m
3
3.7 m
11.6 m
Never use more than three mirrors per device.
Any dust or dirt on the mirror’s reflective surface will drastically reduce the operating range.
2.2.5 Inspections following a first-time installation
Listed below are the control measures that must be taken following a first-time installation,
prior to starting the machine. Tests must be carried out by qualified personnel or directly by
the person in charge of machinery safety / under his or her supervision.
Fig. 16Path of test object
1003067-EN-04
21