OPERATING MANUAL PSEN op4F/H-A series
Fig. 30 Safety report
Identification of light curtain
Serial no.
Firmware version
Configuration ID (check sum of configuration parameters)
Position of light curtain in a cascading
Model name and characteristic data of the light curtain (resolution)
Current protected field configuration (muting or blanking)
Configuration parameters for blanking/muting
6.1 Reset to factory configuration
The user has the option to re-establish the light curtain’s factory configuration by operating
the pushbuttons as described below:
1. Press the CONFIRM button and keep it held down for at least 9 s (but not more than
30 s, so that the light curtain is not blocked)
2. The LEDs flash briefly, indicating that the light curtain has been reset to the factory
configuration
3. After the reset has occurred, the light curtain resumes its normal operation with t
he
f
actory configuration.
NOTE: Restoring the factory settings will delete the BCM and the ACM
configuration.
1003067-EN-04
35

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PSEN op4F-A Series and is the answer not in the manual?

Pilz PSEN op4F-A Series Specifications

General IconGeneral
BrandPilz
ModelPSEN op4F-A Series
CategorySafety Equipment
LanguageEnglish

Related product manuals