OPERATING MANUAL PSEN op4F/H-A series
List of RX functions in blanking mode
(LED 3 OFF)
Function
LED
No.
Setting
LED status
PWR
OSSD
EDM
ACM
LEVEL
Coding
2
Code 1
Code 2
No code
Selection of
muting/blanking
3
Muting
Blanking
EDM
4
Activated
Deactivated
Restart mode
5
Auto
Manual
Selection of
floating blanking
6-7
Floating blanking
deactivated
Floating blanking 1 beam
Floating blanking 2 beams
Reduced resolution 4 beams
Selection of fixed
blanking
8
1 fixed blanking zone
2 fixed blanking zones
List of TX functions
Function
LED
No.
Setting
LED status
PWR
TST
SR
LR
CODE
Coding
2
Code 1
Code 2
No code
Selection of
operating range
3
Normal
Reduced
1003067-EN-04