Operation
Operating Manual PSEN sc B 5 Series
1004508-EN-02
60
Message
(shown in the display)
Error/cause Description/measure
ITLOCK1
OSSD must be restarted Reset the safety laser scanner.
WAINP
The safety laser scanner expects an
input.
Check the wiring. Check the installation
procedure.
10.2 Display during normal operation
Icon
(shown in the display)
Status Description/measure
Device is switched on and opera-
tional
Warning zone has been violated A violation of the warning zone has been
detected. The configured action for a viol-
ation of the warning zone has been
triggered.
Safety zone has been violated A violation of the safety zone has been
detected. The OSSDs are in the OFF
state.
The front panel must be cleaned Decommission the safety laser scanner
and clean the front panel of the safety
laser scanner.
Restart is running Restart of the safety laser scanner is per-
formed.
Download of a configuration or a re-
port
A configuration or a report is downloaded.
The status of the network is checked The status of the safety laser scanner in
the network is checked.
Safety laser scanner in interlock con-
dition
The safety laser scanner is in interlock
condition. Normal operation is possible
only after a successful restart of the safety
laser scanner.
Faulty input Faulty input, e.g. wrong number of inputs
that are used for switching the zone sets.
The status of the network is checked The status of the network is checked.