Captain-i Installation Guide 33
Par. Descr. Settings
S Invert Smoke The smoke output will work in an inverted manner from the
ordinary situation, i.e. when a “+” is displayed under the
letter S, the smoke output is disengaged in an ordinary
situation, and during an event (if thus programmed), the
smoke output will be switched to GND. This is useful when
this output is used to operate a Piezo siren or as an output
to track the siren state. The length of time that the smoke
output is active may be programmed in section Setting
siren and smoke output parameters on page 29.
S 2 Ring
Snapping
“+“ Enables this feature. To do so:
1. Call the system wait for 2 rings and hang up
2. Wait 5 seconds.
3. Call the system again.
4. The system will pick up the line immediately
5.4.6 System configuration 5 (config 5)
[ [
X5
:
BKB2LS4ByPsReprt
------- Config 5
Par. Descr. Settings
B Bypass
Report
“+“ The panel will report the CMS when a zone is
bypassed
K RX-130
Keypad
Selecting keypad type
B Bypass
Request
“+” While arming the system, if one or more zones that
are programmed to be “Delayed” or “Entry Follower”
are opened, the system will alert.
“-“ Only the immediate zones will alert
2 EOL 2 Res. All zones are defined as 2 EOL (End of Line) protected
L Listen-in For operation of microphone with CMS. Zones that are
programmed to operate PGM (see “Zone responses” on
page 22), and Delayed PGM (see System configuration 3
(config 3) on page 31), will activate the microphone after
reporting to the CMS, and will keep the line open for 3
minutes.
Note: Relevant only for ContactID
S Delay Smoke When a voice unit is connected to the SMOKE output, the
output will switch the “-“ only after the system completes
dialing a subscriber (so that the recorded message will not
be heard at the same time as the dialing is occurring, which
could cause communications problems)
4 RXN-406
Keypad
Selecting keypad type. See the following table.

Table of Contents