Captain-i, Installation Guide 34
LED Keypad Used K 4
RX-180, RXN-200 - -
RX-6 / RX-406 - +
Not Used + +
Table 5. Selecting Keypad Type
5.4.7 System configuration 6 (config 6)
[ [
X6
: User code #8 as panic code
PDX User 8=Panic
--- Config 6
Par. Descr. Settings
P Panic “+” Entering User code #8 will send panic alert to the CMS
D Disable Arm
with fails
“+” The system cannot be armed in case of AC or telephone
failure or low battery
X Not in use
-
5.4.8 System responses to faults and events
Note: Response Time: Time between the moment the system identifies a fault until it
is reported. Each fault has a different time response. Response time zero means
immediate report.
[ : Panic code entered
SPGF Siren
---- Panic Resp
.
Par. Descr. Settings
S Siren “+” The siren is triggered
P Communication “+” The system will dial and/or send radio transmission to
the Monitoring Station and the private account (if
programmed.)
G PGM “+” PGM output is triggered
F Fire “+” Smoke output is triggered
[ : AC failure
SPBG Siren
---- AC fail
Par. Descr. Settings
S Siren “+” The siren is triggered
P Communication “+” The system will dial and/or send radio transmission to
the CMS and the private account
B Buzzer “+” keypad buzzer activated
G PGM “+” PGM output is triggered
[ : Enter AC failure response time in minutes
[ : Battery failure
SPBG Siren
---- Bat fail