HUNTER-PRO 32 Intruder Alarm System - Installation Manual
18
The system can detect movement in the protected area via its
connected detectors and sensors, therefore, it can identify no-
movement hence there is no one in the protected area.
When the system starts auto-arming, the display will show
“Automatic Arming” and a 45 seconds ‘warning countdown’ will start,
indicating the arming countdown is to follow. Note that during the
‘warning countdown’ the keypad will beep. During the ‘warning
countdown’, any disarming code can cancel the auto-arming process.
After the ‘warning countdown’ is over, the system will begin regular
arming process, including exit delay and a beep from the keypad.
3.4.1 Programming Auto-Arming at Preset time
Master Code /Enabled User Code
User Menu
Choose 1,2...
-OR-
User Code
User Menu
Choose 1,2...
The following screen will appear:
Automatic Arming
ENTER/NEXT/END
Press
and move to the next screen:
Automatic Arming
XX:XX
Enter
Time in which the system will be armed
NOTE:
To cancel Auto-Arming, the Automatic Arming programming needs to be
repeated, and the time to be set as 00:00.