HUNTER-PRO 32 Intruder Alarm System - Installation Manual
14
3.1 Arming/Disarming via Keypad
3.1.1 System Messages During Arming
3.1.1.1 Arming with Closed Zones (normal arming)
Before arming the system, make sure all zones (except exit delayed
zones – usually zones on exit route) are closed: make sure that in
the keypad display above/below all the LCD zones numbers there is
not a
_ sign blinking or an opened zone indication.
The system can be activated using one of the following codes:
Master Code, User Code, and Short Code.
After entering one of these codes, the green control LED shall begins
to blink, a beep will be heard from the keypad, and the display will
show the exit delay message:
Arming...
Exit Delay 25
At the end of the exit delay, the green control LED shall stop to blink
and stay on, the beep will stop, and the display will show the
following message: “System Set” and then change to the
following display (example):
1 JAN 04 20:05
3.1.1.2 Arming with Open Zone(s)
When activating the system with one or more opened zones (that
are not on the exit route, i.e., exit delayed zones), the keypad will
produce a fast-beep and the display will show:
Open Zone! Press
OP:TOM ROOM
…
Bypass or END
OP:FRONT DOOR
To bypass open zones:
open zones are bypassed & system
armed
Scrolling line: Open Zones & Events