LANCE
II
SERVICE
MANUAL
28
1. OXYGEN
BOTTLES
2.
MOUNTING
BRACKET
3.
FACE
MASK
Figure
14-16.
Oxygen
Installation.
Table
XIV-V.
Oxygen
System
Component
Limits
Parts
Regulator
Pressure
Gauge
Outlets
Recharge
Valve
Masks
Inspection
300
Flight
Hrs.
300
Flight
Hrs.
300
Flight
Hrs.
Each
Use
Each
Use
Overhaul
3
yrs.
3
yrs.
3
yrs.
Replace
every
3
yrs.
Replace
as
necessary
14-51.
TESTING
FOR
LEAKS.
Apply
detector
fluid
type
CD-I
solution
or
its
equivalent.
The
solution
should
be
shaken
to obtain
suds
or
foam.
The
suds
or
foam
should
be
applied
sparingly
to
the
joints
of
a closed
system.
Look
for
traces
of
bubbles.
No
visible
leakage
should
be
found.
Repair
or
replace
any
defective
parts
and
retest
system.