PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 51
AccessingFryerforServicing
1. Shut off the main gas supply line.
2. Shut off the individual gas supply line.
CleaningtheGasValveVentTube
See “Cleaning the Gas Valve Vent Tube” on page 13.
CheckingtheBurnerManifoldGasPressure
TakinganIncomingSupplyGasPressureReading
4. Connect the manomet
er.
1. Unscrew and remove the gas supply plu
g with a
3/16 inch hex wrench.
5. Turn on the main gas supply
line.
2. Finger tighten the test fitting int
o the test port.
3. Finish tightening the test fitting using a 7/16
inch open-ended wrench.